EVERSPRING AN158-2 PDF

It reports both the actual consumption in Watts and the accumulated usage in KWh. The device is rated IP20, hence only for indoor dry environments. When important devices are hooked up to the AN, watch our for power failures :. Apparently the AN does not switch automatically to its previous state. In my case it was connected to a freezer; luckily I remembered to manually switch the AN on after power was restored.

Author:Duzahn Vogul
Country:Australia
Language:English (Spanish)
Genre:Music
Published (Last):23 July 2016
Pages:180
PDF File Size:7.38 Mb
ePub File Size:20.72 Mb
ISBN:280-2-16609-665-1
Downloads:5304
Price:Free* [*Free Regsitration Required]
Uploader:Dugrel



The device is in the category of Power Outlet , defining Small devices to be plugged into a power socket in a wall which stick there. The AN supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the Switch item type The following table provides a summary of the 3 configuration parameters available in the AN Detailed information on each parameter can be found in the sections below.

Time of switching status to send status message This is the time the switching status needs to remain unchanged after a change to cause the device to send out a status message Values in the range 0 to may be set.

Enable or Disable the status message function Enable or Disable the status message function when the local button press changes the switching state. The following option values may be configured Autoreporting meter value interval The device will report its meter value within the interval set.

Set to 0 will disable the autoreporting function. Values in the range 0 to may be set. Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here. Electric meter kWh Indicates the energy consumption kWh. Electric meter watts Indicates the instantaneous power consumption. Reset the meter Reset the meter.

Alarm Indicates if an alarm is triggered. The manufacturer defined default value is Parameter 2: Send Out Basic Command Enable or Disable the status message function Enable or Disable the status message function when the local button press changes the switching state.

The following option values may be configured -: Value Description 0 Disabled 1 Enabled The manufacturer defined default value is 0 Disabled. Parameter 3: Meter Report Period Autoreporting meter value interval The device will report its meter value within the interval set. The manufacturer defined default value is 3.

Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. The AN supports 2 association groups. Group 1: Reports Association group 1 supports 1 node. Group 2: Control Association group 2 supports 4 nodes.